CVE-2026-84411 root cause notes and a non-destructive probe (RouterOS before 7.24)
RouterOS www (the process behind the WebFig administrative interface and the
hotspot portal) contains a pre-authentication integer underflow in the HTTP request
body length accounting. A single unauthenticated request takes the web management
service down: on the administrative interface the outage persisted until a reboot in
our tests, while on the hotspot portal the result varied between a few seconds of
unavailability and a persistent outage. The same read also performs an out-of-bounds
heap write; remote code execution was not demonstrated.
The linkage to CVE-2026-84411 is based on the public description and the fixed version line, and it has not been confirmed by the vendor directly. The binary version evidence and its conflict with the advisory are described in the main report.
The exact trigger is intentionally not published. A public scanner for this CVE was published earlier by others; this repository does not claim priority.
python3 probe_84411.py 127.0.0.1 8180 # WebFig endpoint
python3 probe_84411.py 127.0.0.1 8282 --path /login # hotspot portal
The probe speaks the WebFig transport handshake and reports whether the endpoint answers. It does not demonstrate the vulnerability. Use it only against systems you own or are authorised to test.