Detection-only local triage scanner for CVE-2026-58115 (CVSS 10.0) in Siemens SIMATIC IoT2050 Node-RED: grades Industrial OS versions against V4.3.4.1 and settings.js for adminAuth. No payloads, no remote probing.
node-red-scannerLocal triage for CVE-2026-58115, the 10.0 missing-authentication flaw in Node-RED on Siemens SIMATIC IoT2050 Advanced gateways. Give it an Industrial OS version you own, or a settings.js file you own, and it tells you whether that install is still open. It never touches the network, never probes a server, never deploys a flow, never sends a payload.
The flawNode-RED is a flow-based editor built on Node.js, and it is wired into industrial kit: Siemens embeds it in the SIMATIC IoT2050 Advanced gateway. On affected gateways the Node-RED HTTP interface does not enforce authentication, so an unauthenticated remote attacker can create malicious flows and execute arbitrary code on the underlying server with maximum privileges.
In Node-RED terms that is one request. An inject node wired to an exec node fires as soon as the flow is deployed, and the exec node runs shell commands. VulnCheck caught exactly that in the wild on 30 October 2026: a single POST /flows deploying an auto-triggering flow that pulled a Linux bot binary, plus later attempts that installed persistent webshells instead. Between 30 October and 1 November the same source hit this flaw 16 times. The tool does not reproduce any of that. Its job is to tell you, before an attacker does, whether your install is open.
What it checksAn Industrial OS version you supply (--industrial-os 4.3.4.0): graded against the Siemens fixed build, for IoT2050 Advanced gateways onlyA settings file you supply (--settings settings.js): graded for a live, uncommented adminAuth, for any standalone Node-RED installThis host (--local): the settings.js in the usual Node-RED user directories, or NOT FOUNDA flows file you supply (--flows flows.json): an offline audit for compromise indicators, graded REVIEW, never a compromise verdict on its ownAn offline inventory (--inventory-json inventory.json): a JSON list of {name, industrial_os} entries, for a fleet of gatewaysThe full table (--list): the affected range and the fixed buildThe trap: this is a configuration flaw, not a version flawSignal | Affected | Fixed |
|---|---|---|
SIMATIC IoT2050 Advanced (6ES7647-0BA00-1YA2), Industrial OS with Node-RED installed | below V4.3.4.1 | V4.3.4.1 or later |
Standalone Node-RED, any version | settings.js with no live adminAuth | adminAuth set, or disableEditor: true |
Do not grade a Node-RED version number against this CVE. There is no Node-RED release that fixes it, because the flaw is missing authentication, not a bug in a particular release. Upgrading Node-RED while leaving adminAuth unset leaves the editor exactly as open as before. On an IoT2050, the fix is the Industrial OS update to V4.3.4.1 or later, which enforces authentication on the web interface. On a standalone install, the fix is setting adminAuth in settings.js yourself.
Two more things to not get wrong. First, a commented-out adminAuth is not authentication. The tool strips // and /* */ comments before grading, so a settings file that only mentions adminAuth in a comment still grades VULNERABLE. Second, an exec node in a flows file is not proof of compromise. Plenty of legitimate flows use exec nodes, so the flows check grades REVIEW and tells a human what to look at: exec nodes, http-in nodes wired to exec nodes, and the observed dropper markers (/dev/shm drops, bot-linux-amd64). A CLEAN flows grade means none of those markers are in that file, nothing more. It says nothing about flows that were deployed and deleted.
Usage# vulnerable gateway
python3 node_red_scanner.py --industrial-os 4.3.4.0
# fixed gateway
python3 node_red_scanner.py --industrial-os 4.3.4.1
# standalone install, open editor
python3 node_red_scanner.py --settings ~/.node-red/settings.js
# offline compromise-indicator audit of a flows file you own
python3 node_red_scanner.py --flows flows.json
# on the host itself
python3 node_red_scanner.py --local
# machine-readable output for fleets
python3 node_red_scanner.py --industrial-os 4.3.4.0 --json
# the full fixed-version table
python3 node_red_scanner.py --list
Exit codes: 0 = nothing vulnerable found, 2 = vulnerable or review finding, 1 = scan error. UNKNOWN does not change the exit code, but it is not clean.
Where sources disagree, and what is still unverifiedFirst, the timeline. Siemens published advisory SSA-834709 on 11 August 2026, and CISA advisory ICSA-26-237-03 followed the same month. At that point CISA reported no confirmed in-the-wild exploitation. That changed at the end of October: VulnCheck caught exploitation on 30 October, reported it on 2 November, and The Register covered it the same day. This tool follows the November exploitation evidence, not the August position, and it says so plainly: this is a newly exploited flaw, not a newly disclosed one. The trend trigger here is the 2 November exploitation report, inside the last 72 hours.
Second, KEV status. As of this build, the flaw sits in VulnCheck's KEV catalogue, not in CISA's KEV, per both VulnCheck and The Register. Do not cite it as a CISA KEV entry until CISA lists it.
Third, scope. The Siemens advisory covers only SIMATIC IoT2050 Advanced (6ES7647-0BA00-1YA2) running Industrial OS with Node-RED installed. The underlying condition, an unauthenticated Node-RED editor, applies to any Node-RED install without adminAuth, and the settings check grades that separately, labelled as a standalone grade, not as a Siemens range claim. VulnCheck notes Emerson documentation also highlights Node-RED use but has not validated whether its products are impacted; this tool makes no claim about Emerson kit.
Fourth, no widely available local triage scanner for this flaw was found when this build was checked. What exists is log detection: Sigma / Splunk / KQL rules for the POST /flows deploy pattern, and VulnCheck's own detection. Those watch traffic after the fact. This tool is the other side of that: an offline check of the version and the configuration before anything is deployed. If a standalone scanner already covers this well, open an issue and say so.
Mitigation if you cannot patch todayUpdate is the fix; there is no configuration workaround on the gateway beyond the update itself, per Siemens. Until you can update, do what the advisory says: uninstall Node-RED if you do not need it, harden the install per the Node-RED user guide, and never leave the admin interface, port 1880 included, reachable from the public internet. Put it behind a firewall, a VPN, or a reverse proxy with multi-factor authentication. For a standalone install, setting adminAuth today closes the hole this CVE describes, and reviewing deployed flows for unauthorised exec nodes or undocumented http endpoints is the compromise check to run alongside it.
Testspython3 -m unittest discover -s tests -v
19 tests: Industrial OS versions below and above the fixed build, unparseable versions as UNKNOWN, adminAuth present, absent and commented-out, disableEditor, clean flows, exec nodes, http-in wired to exec, dropper markers, invalid flows JSON, CLI exit codes, JSON output, the full table, and the inventory file.
Thanks toSiemens ProductCERT, for advisory SSA-834709 and the fixed Industrial OS build this tool grades againstVulnCheck, for catching the in-the-wild exploitation and publishing the analysis this build is timed onCISA, for advisory ICSA-26-237-03 and the affected-product scopeNode-RED project, for the adminAuth and disableEditor settings this tool gradesDisclaimer