CVE-2026-58115
A vulnerability has been identified in SIMATIC IoT2050 Advanced (6ES7647-0BA00-1YA2) (All versions < V4.3.4-1 running Industrial OS with Node-RED...
- Published
- Aug 11, 2026
- Updated
- Nov 10, 2026
- Assigning CNA
- siemens
- Evidence observed
- Nov 5, 2026
Primary CVSS
nvd · CVSS 4.0
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:XLow · next 30 days
- Percentile
- 59.5%
- Model date
- Nov 4, 2026
EPSS is a statistical estimate, not a certainty or a measure of impact. Combine it with CVSS, KEV status, exposure and your environment.
Summary
A vulnerability has been identified in SIMATIC IoT2050 Advanced (6ES7647-0BA00-1YA2) (All versions < V4.3.4-1 running Industrial OS with Node-RED installed), SIMATIC IoT2050 Advanced (6ES7647-0BA00-1YA2) (All versions running Example Image versions with Node-RED installed), SIMATIC IoT2050 Basic (6ES7647-0BA00-0YA2) (All versions < V4.3.4-1 running Industrial OS with Node-RED installed), SIMATIC IoT2050 Basic (6ES7647-0BA00-0YA2) (All versions running Example Image versions with Node-RED installed), SIMATIC IoT2050 M.2 (6ES7647-0BB00-1YA2) (All versions < V4.3.4-1 running Industrial OS with Node-RED installed), SIMATIC IoT2050 M.2 (6ES7647-0BB00-1YA2) (All versions running Example Image versions with Node-RED installed), SIMATIC IoT2050 SM (6ES7647-0CA00-1AA2) (All versions < V4.3.4-1 running Industrial OS with Node-RED installed), SIMATIC IoT2050 SM (6ES7647-0CA00-1AA2) (All versions running Example Image versions with Node-RED installed). Affected devices do not enforce authentication on the Node-RED HTTP interface, allowing unauthenticated access to programming nodes that are capable of executing system commands on the server. This could allow an unauthenticated remote attacker to create malicious flows through the HTTP interface in order to execute arbitrary code on the underlying server with maximum privileges.
Sources
PoC, non-destructive scanner, Docker lab, PCAP and Suricata/Sigma detection rules for CVE-2026-58115, unauthenticated root RCE via the Node-RED admin API on Siemens SIMATIC IoT2050.
- node-red-scannerScanner
Detection-only local triage scanner for CVE-2026-58115 (CVSS 10.0) in Siemens SIMATIC IoT2050 Node-RED: grades Industrial OS versions against V4.3.4.1 and settings.js for adminAuth. No payloads, no remote probing.
Responsible use
Use vulnerability information only on systems you own or are authorized to test. Kitploit links to public research metadata and does not store exploit code or malicious payloads.