PoC-Modbus-TCP-Exploit, der manipulierte Schreibzugriffe auf schreibgeschützte Coils in simulierten SPS demonstriert und Schwachstellen in der Zugriffskontrolle von SCADA/ICS aufzeigt.
# modbus_plc_sim.py - Simulated Modbus PLC with read‑only coils
from pymodbus.server.sync import StartTcpServer
from pymodbus.device import ModbusDeviceIdentification
from pymodbus.datastore import ModbusSequentialDataBlock
from pymodbus.datastore import ModbusSlaveContext, ModbusServerContext
store = ModbusSlaveContext(
di=ModbusSequentialDataBlock(0, [1]*100), # coils – should be read‑only
co=ModbusSequentialDataBlock(0, [0]*100), # discrete inputs
hr=ModbusSequentialDataBlock(0, [0]*100),
ir=ModbusSequentialDataBlock(0, [0]*100)
)
# Vulnerability: coil block (di) is writable via function code 5 (Write Single Coil) normally, but maybe misconfigured.
# To simulate a flaw, we'll allow writing to coils using function code 15 (Write Multiple Coils) even though they should be read‑only.
# The pymodbus default allows writing to coils. We'll just demo writing to a coil that is supposed to be safety‑critical.
context = ModbusServerContext(slaves=store, single=True)
StartTcpServer(context, address=("0.0.0.0", 5020))
Eine industrielle SPS legt Coils offen, die als schreibgeschützt vorgesehen sind (z. B. Alarmzustände). Aufgrund eines Konfigurationsfehlers akzeptiert der Modbus-Server jedoch Schreibbefehle (Funktionscode 5 oder 15) auf diese Coils, sodass ein Angreifer Sicherheitssysteme manipulieren kann.
pip install pymodbus
python modbus_plc_sim.py
python exploit_modbus_write.py