CVE-2012-1803
Critical vulnerability in Siemens RuggedCom ROS devices allowing attackers to derive a hidden factory account password from the device MAC address…

Critical vulnerability in Siemens RuggedCom ROS devices allowing attackers to derive a hidden factory account password from the device MAC address…

Open-source forensics framework for analyzing Industrial PLC metadata and project files. Scans for suspicious artifacts in ICS environments to…

Redefining vulnerability disclosure in the AI era. We mass-produce exploitable 0days and disclose them directly, using event-driven pressure to…

A Zeek package for the passive detection of "Ripple20" vulnerabilities in the Treck TCP/IP stack.

Analyzing and Reproducing the Command Injection Vulnerability (CVE-2023-0861) in NetModule Routers

Proof-of-concept exploit for authentication bypass via capture-replay in Dingtian DT-R002 relay, allowing unauthorized control of relays through HTTP…

PoC Modbus TCP exploit demonstrating spoofed writes to read-only coils in simulated PLCs, highlighting SCADA/ICS access control flaws.

CVE-2018-11517 | mySCADA myPRO v7.0.46 has another vulnerability to discover all projects in the system.

Public technical advisory and reproduction evidence for CVE-2026-52134 affecting GOOSE replay handling in libiec61850 v1.6.

Simple script to exploit open redirection vulnerability in Rockwell ControlLogix 1756-ENBT/A

Active Scanning and Information Gathering in ICS/SCADA Networks using Network Mapper (NMAP) (Turkish)

PoC exploit for CVE-2025-69985: authentication bypass leading to RCE in FUXA SCADA ≤1.2.8. Includes a modular Python exploit with interactive shell,…

Benign proof-of-concept for CVE-2026-36226, a cross-site scripting vulnerability in Advantech WebAccess/SCADA 8.0-2015.08.16 Admin Dashboard Create…

There is a path injection vulnerability in OpenPLC-v3, which arises from the program not performing any validity checks on the file path parameters…

Proof-of-concept exploit for CVE-2021-41579 enabling arbitrary file write/read and RCE via malicious .els project file in LAquis SCADA ≤4.3.1.1085.

OpenPLC Runtime suffers from a persistent denial of service (DoS) vulnerability in the /upload-program-action endpoint.

Exploit for CVE-2021-31630 in OpenPLC, providing a Python script and manual steps to achieve remote code execution via malicious ST file upload and…

Authenticated users can upload arbitrary files (e.g. .html, .svg) as profile images in OpenPLC Runtime. These files are publicly accessible without…