CVE-2026-21006-Zigbee-Light-Link-Factory-Reset-Exploit — Simulated Zigbee Light Link (ZLL) factory reset exploit for CVE-2026-21006, demonstrating unauthenticated TouchLink command injection that wipes device network keys and enables IoT device hijacking. | Kitploit
Tools/GitHubGitHub/george0papasotiriou/cve-2026-21006-zigbee-light-link-factory-reset-exploit
Embedded Systems SecurityIoT SecurityVulnerability AnalysisExploitationWireless SecurityHardware & IoT Security
GitHubgeorge0papasotiriou/cve-2026-21006-zigbee-light-link-factory-reset-exploit

CVE-2026-21006-Zigbee-Light-Link-Factory-Reset-Exploit

Simulated Zigbee Light Link (ZLL) factory reset exploit for CVE-2026-21006, demonstrating unauthenticated TouchLink command injection that wipes device network keys and enables IoT device hijacking.

Most Popular

View all →

Discover the most used tools by our community.

Explore all tools

Browse our collection of tools

View all tools →
Share
View Repository
411 month agoNot yet reviewed

CVE-2026-21006 – Zigbee Light Link Factory Reset Exploit

Program Code (Python Zigbee simulation)

root@kitploit:~
# zigbee_factory_reset.py - Simulated Zigbee coordinator sending factory reset command
import time

class ZigbeeDevice:
    def __init__(self):
        self.network_key = b'secret'
    def receive_command(self, cmd_id):
        if cmd_id == 0x00:  # Factory Reset
            print("Device factory reset! Network key cleared.")
            self.network_key = None

device = ZigbeeDevice()
# Attacker sends a specially crafted ZLL touchlink command (simulated)
print("Sending TouchLink factory reset command...")
device.receive_command(0x00)

CVE-2026-21006 – Zigbee Light Link Factory Reset Exploit

Severity: High

Overview

Zigbee Light Link (ZLL) devices support a factory reset via a TouchLink commissioning command that can be sent by any nearby ZLL controller. An attacker can force a device to reset, removing its network credentials and allowing take‑over.

Vulnerability Details

  • Type: Unauthenticated Command Injection
  • Impact: Device hijacking, network disruption.
  • Root Cause: ZLL specification allows factory reset commands without authentication for proximity‑based convenience.

Exploit Demonstration

Run the simulation:

root@kitploit:~
python zigbee_factory_reset.py

The device erases its network key upon receiving the command.