The Sinilink XY-WFT1 WiFi Remote Thermostat, running firmware 1.3.6, allows an attacker to bypass the intended requirement to communicate using MQTT. It is...
- Published
- Jan 20, 2023
- Updated
- Apr 2, 2025
- Assigning CNA
- mitre
- Evidence observed
- Aug 8, 2026
Primary CVSS
nvd · CVSS 3.1
CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:H/A:NLow · next 30 days
- Percentile
- 78.1%
- Model date
- Sep 21, 2026
EPSS is a statistical estimate, not a certainty or a measure of impact. Combine it with CVSS, KEV status, exposure and your environment.
Summary
The Sinilink XY-WFT1 WiFi Remote Thermostat, running firmware 1.3.6, allows an attacker to bypass the intended requirement to communicate using MQTT. It is possible to replay Sinilink aka SINILINK521 protocol (udp/1024) commands interfacing directly with the target device. This, in turn, allows for an attack to control the onboard relay without requiring authentication via the mobile application. This might result in an unacceptable temperature within the target device's physical environment.