CVE-2018-10594
Delta Industrial Automation COMMGR from Delta Electronics versions 1.08 and prior with accompanying PLC Simulators (DVPSimulator EH2, EH3, ES2, SE, SS2 and...
- Published
- Jun 26, 2018
- Updated
- Sep 16, 2024
- Assigning CNA
- icscert
- Evidence observed
- Jul 2, 2018
Primary CVSS
nvd · CVSS 3.0
CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:HHigh · next 30 days
- Percentile
- 99.3%
- Model date
- Oct 13, 2026
EPSS is a statistical estimate, not a certainty or a measure of impact. Combine it with CVSS, KEV status, exposure and your environment.
Summary
Delta Industrial Automation COMMGR from Delta Electronics versions 1.08 and prior with accompanying PLC Simulators (DVPSimulator EH2, EH3, ES2, SE, SS2 and AHSIM_5x0, AHSIM_5x1) utilize a fixed-length stack buffer where an unverified length value can be read from the network packets via a specific network port, causing the buffer to be overwritten. This may allow remote code execution, cause the application to crash, or result in a denial-of-service condition in the application server.
Sources
modules/exploits/windows/scada/delta_ia_commgr_bof.rb
Metasploit Framework modulesDeclared conditions
- platform: Windows($.exploit_windows/scada/delta_ia_commgr_bof.platform)
- verification: check_not_declared($.exploit_windows/scada/delta_ia_commgr_bof.check)
Responsible use
Use vulnerability information only on systems you own or are authorized to test. Kitploit links to public research metadata and does not store exploit code or malicious payloads.